These basic principles apply to all our precision switches. The specific characteristics of each model are given in more detail in the relevant product sections.

Introduction

Our microswitches are high-precision, snap-action microswitches and these are the main features for which they are notable :

■ High ratings but small dimensions

■ Very short travel

■ Low operating force

■ High reliability of travel and force values

■ Long life

■ Large range of actuators for easy adaptation to the most varied applications

Microswitch construction

Single-pole changeover microswitch (e.g. “V3” 83 161)

Double-pole changeover microswitch (e.g. 83 132 0)

The NO and NC circuits must both be of the same polarity.

Mechanical characteristics

Terminology - Forces - Positions - Travel

Graphs of forces vs. travel

Mechanical characteristics

? Changeover time

This is the time taken by the mobile contact when moving from one fixed contact to another until it becomes fully stable (contact bounce included).This time is a function of the contact gap, the mechanical characteristics of the snap action and the mass of the mobile element.

However, thanks to the snap-action mechanisms employed, the time is largely independent of the speed of operation.

It is normally less that 20 milliseconds (including bounce times where less than 5 ms).

? Mechanical durability

This is an average value indicating the purely mechanical performance of a microswitch when not subject to any electrical load. It may be useful for evaluation purposes in cases where the power levels involved are very low and the electrical life is thus close to the mechanical life.

? Maximum speed and rate of operation

Our microswitches will work at speeds of operation varying over a very wide range : normally from 1 mm/min to 1 ms.

The maximum rate of operation with a low electrical load may be as high as 10 operations/second.

? Mounting - Operation

? To conform to the leakage paths and air gaps in the standard EEC24

- EN/IEC 61058 - EN/IEC 60947:

■ An insulation pad must be inserted between the microswitch and the fixing surface if the latter is metal.

■ Manual operation of a metal actuator must only be carried out with the help of a secondary actuator made of insulating materials.The installer must ensure adequate protection against direct contact with the output terminals.

? Fixing - Screw torque

? Unless otherwise indicated in the mechanical characteristics table, the torque required for the fixing screws must conform to the following values :

Environmental conditions

? Resistance to shocks and vibrations

Resistance to impact and vibration depends on the mass of the moving parts and on the forces holding the contacts together.

Generally speaking, for a microswitch without an actuator :

■ Vibration >10 G 10 at 500 Hz

■ Impact > 50 G 11 ms 1/2 sine

Further information on request.

? Ambient operating temperature

The maximum and minimum temperatures at which the mechanical and electrical characteristics of the microswitch will remain substantially unaltered.

? Degree of protection

Under the IEC 529 or NFC 20010 classification scheme, standards employ an IP code to define the degree or class of protection which electrical equipment provides against access to live components, the entry of solid foreign bodies and ingress of water.

Under this classification, our microswitches come within the following

categories :

■ Plain microswitches = IP 00

■ Protected microswitches = IP 40 with isolated connection

■ Sealed microswitches = IP 66 or IP 67

Dielectric characteristics

? Current rating

This is the current the microswitch is capable of making and breaking,which forms the basis for the life tests.

?Thermal rating

This is the current the microswitch will withstand when not being operated,for a temperature rise of not more than 60°C.

? Switch rating

AC voltages : see the current rating

With DC voltages the switch rating is very much dependent on the voltage,the contact gap and the nature of the load being switched. There is a risk of prolonged or indeed permanent arcing if the following limits are exceeded:

? Operating curves

These indicate the electrical life of the microswitches, under standard conditions (20°C, 1 cycle/2 seconds), by showing the number of switching operations which can be performed with given types of load.

Note : for sealed products and D.C. ratings, the operating rate is 1 cycle/6 seconds.

Circuit types

? Resistive circuit

For a circuit with alternating voltage, this is in phase with the current : Cos ? = 1.

? Inductive circuit

A circuit of this type with direct current is characterised by a time constant. An inductive circuit, with alternating voltage, for example, incorporating a motor (cos ? < 1) can cause current surges up to 6 times the nominal current. For certain switches, we give electrical endurance curves with L = 5 ms in DC R and cos ? = 0.8 in AC.

? Lamp and capacitance circuit In this case, currents at the closing of the circuit have high value, up to 10 times the normal rating.

? Internal resistance

This consists of the intrinsic resistance (fixed) of the parts carrying current and the contact resistance (variable). Close to the tripping point and release position, the force holding the contacts together drops considerably and this may cause a significant rise in internal resistance.

? Insulation resistance

The insulation resistance of the microswitches is generally greater than 50 000 MΩ measured at 500 V DC.

? Dielectric strength

The dielectric strength of our microswitches is generally better than :

■ 1500 volts between live parts and earth

■ 1000 volts between contacts

■ 600 volts between contacts for microswitches

whose contact gap is less than 0.3 mm.

Contact materials

? Choice of contact material

To choose the best material for the contacts there are various factors to be considered :

■ the current and voltage levels

■ the type of load

■ the number of operations

■ the switching frequency

■ the environmental conditions

? Contacts for general-purpose use

Our microswitches are normally fitted with silver contacts. These are suitable for the majority of applications and provide the best compromise between electrical performance, thermal performance and life.

? Contacts for low-power circuits

U < 10 V and/or I < 100 mA

The contacts used in this case are plated with gold (or a gold alloy) for good reliability even in corrosive atmospheres.

? Contacts for special applications

We can supply special contacts suitable for particular applications, such as :

■ Ag CdO contacts for very high drawn currents

■ Cross gold-plated Ag Ni contacts which allow a very wide range of applications to be covered by a single type of microswitch.

Electrical recommendations

? Inductive circuits

To increase the life of contacts and their DC rating, arcing on opening can be reduced by using the following circuits :


?Very low-power circuits

In very low-power circuits (I > 1 mA, V ≤ 5 V), switching is highly sensitive (to the atmosphere, pollution). If the supply is powerful enough, adding a passive resistor to increase the current broken by the microswitch to a few milliamps will substantially improve reliability of operation.

R - Load resistance

C - Very low current load


Methods of actuation

? Methods of actuation

Force should preferably be applied to the device to be directly operated- the plunger - along its axis. However, the majority of our microswitches will accept skewed operation provided the angle of application is not more than 45°.

The device used to apply the force must never hamper the travel of the plunger to the tripping point (TP). It must under all circumstances move the plunger through at least 0.5 times the overtravel (OT) quoted. Steps must also be taken to see that it does not cause the OL or MOF quoted to be overrun or exceeded.

? Operation by actuator

When operation is by a roller lever, force should preferably be applied in the direction shown on the left.

Where the movements involved are fast, the ramp should be so designed as to ensure that the operating device is not subjected to any violent impact or abrupt release.

Quality

Crouzet undertakes a pro-active quality policy adapted to our different markets of which the objectives are:

■ To actively contribute to the success to our clients

■ To ensure the perennial development of the company and the brand by achieving global performance (social, economic, product and service offer) in the fi eld of environment and legislation.

?This quality implies:

■ Mobilisation and dynamic behaviour by the entire staff

■ Achieving results and respecting our commitments

■ Sharing our policies with our partners (clients, suppliers…)

?This quality is based on a series of ongoing actions:

■ Focusing on the preventative

- Quality starts from the understanding of the clients needs in order to work out the specifi cations where Crouzet acts as expert advisor.

- Quality is pro-active in actions for progress

- Quality ensures the systematic exploitation of feedback experience, methods and quality tools.

Standards - Approvals

Our microswitches are designed according to international recommendations(IEC), American standards (UL) and/or European standards (EN).Proof of compliance with these standards and recommendations is demonstrated by

■ the manufacturer’s declaration of conformity (drafted in accordance with the ISO/IEC 22 guidelines), or

■ approval granted directly by an accredited body, or by application of the CCA (Cenelec Certification Agreement).

More detailed information on the approval for a particular type of microswitch can be obtained on request.

Rules and regulations

? EC directives

Our microswitches are compatible with European Community technical directive (Low Voltage) 73/23 and can be used within the framework of Machinery  directive 83/392.

? Environmental protection ISO 14001

The modern concept of protection of the environment is an integral part of the manufacture of our microswitches, from product design through to packaging.

下一篇: PLC、DCS、FCS三大控

上一篇: 索爾維全系列Solef?PV

推薦產品

更多
主站蜘蛛池模板: 污水处理设备-海普欧环保集团有限公司| SOUNDWELL 编码器|电位器|旋转编码器|可调电位器|编码开关厂家-广东升威电子制品有限公司 | 搪瓷搅拌器,搪玻璃搅拌器,搪玻璃冷凝器_厂家-淄博越宏化工设备 | 无菌实验室规划装修设计-一体化实验室承包-北京洁净净化工程建设施工-北京航天科恩实验室装备工程技术有限公司 | 聚氨酯保温钢管_聚氨酯直埋保温管道_聚氨酯发泡保温管厂家-沧州万荣防腐保温管道有限公司 | 蓝鹏测控平台 - 智慧车间系统 - 车间生产数据采集与分析系统 | 面粉仓_储酒罐_不锈钢储酒罐厂家-泰安鑫佳机械制造有限公司 | pbt头梳丝_牙刷丝_尼龙毛刷丝_PP塑料纤维合成毛丝定制厂_广州明旺 | 隔离变压器-伺服变压器--输入输出电抗器-深圳市德而沃电气有限公司 | China plate rolling machine manufacturer,cone rolling machine-Saint Fighter | 高压油管,液压接头,液压附件-烟台市正诚液压附件 | 沥青灌缝机_路面灌缝机_道路灌缝机_沥青灌缝机厂家_济宁萨奥机械有限公司 | 上海平衡机-单面卧式动平衡机-万向节动平衡机-圈带动平衡机厂家-上海申岢动平衡机制造有限公司 | Win10系统下载_32位/64位系统/专业版/纯净版下载| 标准光源箱|对色灯箱|色差仪|光泽度仪|涂层测厚仪_HRC大品牌生产厂家 | 北京包装设计_标志设计公司_包装设计公司-北京思逸品牌设计 | 手持气象站_便携式气象站_农业气象站_负氧离子监测站-山东万象环境 | 焊锡丝|焊锡条|无铅锡条|无铅锡丝|无铅焊锡线|低温锡膏-深圳市川崎锡业科技有限公司 | 馋嘴餐饮网_餐饮加盟店火爆好项目_餐饮连锁品牌加盟指南创业平台 | 高压绝缘垫-红色配电房绝缘垫-绿色高压绝缘地毯-上海苏海电气 | 海鲜池-专注海鲜鱼缸、移动海鲜缸、饭店鱼缸设计定做-日晟水族厂家 | 专业生产动态配料系统_饲料配料系统_化肥配料系统等配料系统-郑州鑫晟重工机械有限公司 | 深圳市索富通实业有限公司-可燃气体报警器 | 可燃气体探测器 | 气体检测仪 | 辐射色度计-字符亮度测试-反射式膜厚仪-苏州瑞格谱光电科技有限公司 | 地埋式垃圾站厂家【佳星环保】小区压缩垃圾中转站转运站 | 热熔胶网膜|pes热熔网膜价格|eva热熔胶膜|热熔胶膜|tpu热熔胶膜厂家-苏州惠洋胶粘制品有限公司 | 北京三友信电子科技有限公司-ETC高速自动栏杆机|ETC机柜|激光车辆轮廓测量仪|嵌入式车道控制器 | 防锈油-助焊剂-光学玻璃清洗剂-贝塔防锈油生产厂家 | 首页|专注深圳注册公司,代理记账报税,注册商标代理,工商变更,企业400电话等企业一站式服务-慧用心 | 槽钢冲孔机,槽钢三面冲,带钢冲孔机-山东兴田阳光智能装备股份有限公司 | 快干水泥|桥梁伸缩缝止水胶|伸缩缝装置生产厂家-广东广航交通科技有限公司 | 菏泽知彼网络科技有限公司 | 卫生型双针压力表-高温防腐差压表-安徽康泰电气有限公司 | WF2户外三防照明配电箱-BXD8050防爆防腐配电箱-浙江沃川防爆电气有限公司 | 乙炔气体报警装置|固定式氯化氢检测仪|河南驰诚电气百科 | 黑龙江「京科脑康」医院-哈尔滨失眠医院_哈尔滨治疗抑郁症医院_哈尔滨精神心理医院 | AR开发公司_AR增强现实_AR工业_AR巡检|上海集英科技 | 药品仓库用除湿机-变电站用防爆空调-油漆房用防爆空调-杭州特奥环保科技有限公司 | 企业管理培训,企业培训公开课,企业内训课程,企业培训师 - 名课堂企业管理培训网 | 字典-新华字典-在线字典查字-字典趣 | 避光流动池-带盖荧光比色皿-生化流动比色皿-宜兴市晶科光学仪器 东莞爱加真空科技有限公司-进口真空镀膜机|真空镀膜设备|Polycold维修厂家 |